The joint at the party wall
On a pair of 1930s semis the gutter was once a single run along both halves. On most pairs it no longer is. One side may have been replaced in uPVC years ago, the other more recently in a different profile, and the two meet at the party wall with a joint that was never designed to connect them. Two makes of the same profile with slightly different sizes cause the same trouble as two different profiles.
The fix depends on what is there. Where the profiles match, a new union and seal is usually enough. Where they do not, an adaptor made for the two systems, or a short section replaced on one side so both ends match, gives a joint that stays dry. Either way, the fall is checked on both sides of the line, because a joint that sits in a dip will fail again whatever it is made of.
Since the joint sits on the boundary, you get a price you can share with your neighbour, and the repair goes ahead once you have both agreed to it.
Bay gutters under the half-timbered gables
Many of the semis here have a half-timbered gable over a front bay, with a short gutter at the foot of the bay roof. That little run takes water and moss from the bay roof above and drains through a small outlet, and it is easy to forget because it sits below the main eaves and out of sight from upstairs. The usual faults are a sagging run where the bracket has pulled out of a soft board, a cracked outlet, and a stop end that has come loose and lets water down the brickwork beside the window.
Elsewhere on the house, repairs tend to be re-sealing the angle pieces at the foot of each hip, refixing brackets that have worked loose or adding brackets where they were spaced too far apart, resetting the fall so water reaches the outlet, and reconnecting downpipes that have pulled apart at the side passage. If water is getting behind the gutter instead of over it, our article on water leaking behind a gutter explains the likely causes.
If the fascia behind has gone soft, the gutter will not stay fixed until the board is replaced, and our fascias and soffits work covers that. If the plastic has gone brittle and cracks when touched, a new gutter installation is usually better value than another patch.
On cost, MyJobQuote's gutter repair guide puts the average UK repair at around £215. A single party-wall joint is often less, and a run with several faults more.

Lavender Avenue and the courtyard blocks
Not all housing in North Cheam is pairs of semis. Sutton Council's draft character study gives Lavender Avenue as an example of courtyard block housing, with flats set around a shared garden and front doors opening onto the street. On buildings like these one gutter run serves several homes, so a repair is usually arranged by a managing agent or residents' company, and we can work to their instructions and give a written note of what was found and fixed.
Frequently asked questions
Our side of a North Cheam pair has new uPVC and next door still has an older profile. Can the two be joined so it stops leaking?
Yes. We fit an adaptor made to join the two systems, or replace a short length on one side so the ends match. Sealant alone on two mismatched profiles rarely lasts a winter.
The short gutter over my bay window off London Road is sagging. Does the fascia need replacing too?
Only if the board is soft. If the screws have simply pulled out, the bracket can be refixed into sound timber. If the board crumbles when pressed, it needs replacing before the gutter will hold.
The downpipe by the side passage of my Lavender Estate semi has come apart. Is that a quick repair?
Usually, yes. The sections are rejoined or the broken one replaced, and the clips are refixed to the wall so the pipe stays in line with the shoe at the bottom.